APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21021 Issued:1999-02-18
Revised:2012-04-18
Style 21021 Bonded flat ribbon cable.

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor36 AWG - 26 AWG, solid or stranded.
InsulationExtruded TPE, 4 mils minimum thickness at any point.
AssemblyTwo through 150 insulated singles or twisted pair or triads laid parallel in one plane, retained by heat or film melt bonded section at random intervals up 2 to 100 inch apart, or along the complete length of cable, with or without PVC bands on one side of the cables in between the heat or film melt bonded sections. Width of heat or film melt bonded sections min 1 inch. PVC film, Polyester, Polyester/PVC laminated film may be heat bonded on one or both sides of cable.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.