APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21022 Issued:1999-03-30
Revised:2012-11-15
Style 21022 Parallel Cable with Extruded Integral Insulation and Jacket

Rating60, 75, 90 or 105 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, stranded.
Integral Insulation and JacketExtruded PVC, 45 mils minimum average thickness, 40 mils minimum thickness at any point before separtion, 27 mils minimum thickness at any point after separation. The center conductor shall be insulated with PVC of 15 mils minimum average thickness, 13 mils minimum thickness at any point. 40 mils minimum distance between conductors and the center conductor.
AssemblyThree conductors, same as Type SPT-2. Two 18-16 AWG conductors, stranded, with 36-34 AWG strands and one 26-16 AWG conductor, stranded, with 34 AWG strands. The two 18-16 AWG conductors shall be laid parallel and the 26-16 AWG conductor shall be located between the 18-16 AWG conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Appliances and Electronic Equipment.