Rating | 60 or 80 deg C, 125 Vac, Horizontal Flame (Internal), Cable Flame (External). |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more insulated singles, twisted pairs or groups of twisted insulated singles twisted together or insulated singles or groups of insulated singles may be laid parallel to form flat, oval or round cable. Length of lay not specified. Barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional - A 6 mil or heavier PVC, PE, ETFE or XLPE covering may be extruded over the insulated conductor assembly. |
|
Shield | Optional. |
|
Jacket | PVC |
| major dia. in inches |
| 0.700 or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501-4.00 dia | 110 avg | 88 min |
| 4.001 dia and larger | 140 avg | 112 min.
Extruded PVC |
| Diameter of core assembly under jacket*, Minimum average thickness, Minimum thickness at any point; 0.700 inch or less, 30 mils, 24 mils; 0.701-1.000, 45 mils, 36 mils; 1.001-1.500, 60 mils, 48 mils; 1.501-2.500, 80 mils, 64 mils; 2.501-4.000, 110 mils, 88 mils; 4.001 inch or greater, 140 mils, 112 mils # *Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or External interconnection of electronic equipment. |
|