Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 10 AWG. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure having a minimum rating of 105 deg C, 300 Vac. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. |
|
Jacket | Extruded PVC. |
| Dia. of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.350 inch or less* | 15 mils | 12 mils |
| 0.351-0.700 inch | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| *Major diameter if cable is flat or oval. |
|
Braid | Optional, provided over Jacket. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|