APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21030 Issued:1999-07-19
Revised:2019-11-07
Style 21030 Multiple-conductor cable using non-integral jacket

Rating60, 80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twistedsingles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable.Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of eachassembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC, PE, ETFE or XLPE covering may be extruded over the conductor assembly.
JacketPUR
major dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.00 dia110 avg88 min
4.001 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024