APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21039 Issued:1999-07-16
Revised:2012-07-27
Style 21039 Insulated Cable.

Rating125 deg C, 60 Vac, Horizontal flame.
Conductor36 AWG - 18 AWG , bare, tinned or plated, round or flat. Min thickness of 2.0 mil, max thickness of 6.0 mils. Min width of 10.0 mils, max width of 150 mils.
InsulationPOLYIMIDE, 1 mils min average.
AssemblyTwo to sixty conductors. On each side of conductors, a 1.0 mil min wall of polyimide film with a 0.5 mil of polyester adhesive. Insulation width on outside edges of conductors not less than 10.0 mils and not less than 20.0 mils width of insulation between adjacent conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024