Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | No. 20-16 AWG, tinned or bare consisting of No. 34 AWG copper strands. |
|
Insulation | Extruded PVC, 30 mils minimum average thickness, 27 mils minimum tchicness at any point. |
|
Assembly | Two conductors laid flat. Different conductor sizes may be employed in one cable within this size range. The jacket shall fill the valleys between adjacent conductors. |
|
Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. Nominal 45 mil wall compound along the flat surface of the cable and a nominal 30 mil wall compound along the sides of the cable. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use as Television Remote Control Cable where exposed to temperatures not exceeding 80 deg C. |
|