APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2104 Issued:1959-05-01
Revised:2012-04-17
Style 2104 Multiple Condutor with Extrudet insulation and Ex Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorNo. 20-16 AWG, tinned or bare consisting of No. 34 AWG copper strands.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum tchicness at any point.
AssemblyTwo conductors laid flat. Different conductor sizes may be employed in one cable within this size range. The jacket shall fill the valleys between adjacent conductors.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. Nominal 45 mil wall compound along the flat surface of the cable and a nominal 30 mil wall compound along the sides of the cable.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as Television Remote Control Cable where exposed to temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024