APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21043 Issued:1999-07-23
Revised:2012-03-22
Style 21043 Single Conductor with Extruded Insulation and Covering

Rating150 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 20 AWG, solid or stranded.
InsulationExtruded ETFE, 9 mils minimum average thickness, 8 mils minimum thickness at any point.
AssemblyTwo to six individually insulated conductors or groups of conductors cabled together into a round cable. Lay not specified.
ShieldBraid (85 percent min coverage tinned or bare copper). Over the individual or groups of conductors.
CoveringExtruded ETFE, or PVDF 9 mils minimum average thickness, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseResistance wire for heating mats where the acceptability is determined by Underwriters Laboratories.

UL and the UL Logo are trademarks of UL LLC © 2024