APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21055 Issued:1999-08-26
Revised:2019-11-07
Style 21055 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure, 10 mils min average, 9 mils minimum at any point. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. The length of lay of the twisted conductors or groups is not specified. A barrier layer may be employed.
ShieldOptional.
Jacketextruded PVDF
dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.500 dia45 avg40 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring of appliances of electronic equipment.