APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21056 Issued:1999-08-24
Revised:2011-11-25
Style 21056 Bonded flat ribbon cable.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 9 mils minimum average thickness, 7 mil minimum thickness at any point.
AssemblyTwo to 100 insulated singles or twisted pair or triads laid parallel in one plane, retained by heat or film melt bonded section at random intervals from two to 100 in apart, with or without PVC bands on one side of the cables in between the heat or film melt bonded sections minimum 1 inch width or PVC bands, approximately 0.1875 in.
ShieldOptional.
CoveringOptional. Extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.