Rating | 60 deg C, 300 Vac, Horizontal flame, VW-1 flame. |
|
Conductor | 36 AWG - 30 AWG consisting of 36-30 strands. |
|
Insulation | PVC either Labeled or complies with manufacturer's procedure and min average insulation thickness 9 mils. |
|
Assembly | Four or more singles and optical fiber members cabled around the strength member. The length of lay of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. Manufacturer shall maintain a complete description of each assembly. |
|
Strength Member | Stranded steel with minimum 12 mils polyethylene covering |
|
Shield | Optional. Copper braid only. |
|
Jacket | PVC |
| dia of cable under jacket in inches | minimum average thickness | minimum thickness at any point |
| 0-0.275 | 40 mils | 32 mils |
| 0.276-0.425 | 50 mils | 40 mils |
| 0.425-0.700 | 60 mils | 48 mils |
|
Misc. | Optic Core Coating and Covering - Construction not specified. Strength Member - Stranded steel with minimum 12 mils polyethylene covering. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Remote Control on Interconnecting Cables for use with Professional Video and Audio Equipment in accordance with UL Standard 1419 where the acceptability is determined by Underwriters Laboratories. |
|