APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2106 Issued:1959-05-01
Revised:2011-08-04
Style 2106 Multiple-Conductor Cable Using Non-Integral Jacket

Rating60 deg C, 600 Vac, Horizontal flame
Conductor26 AWG - 12 AWG solid or stranded
InsulationFRPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point
AssemblyTwo conductors.
ShieldShielding over one or both insulated conductors shall consist of No. 36-30 AWG applied as a wrap or braid or a wrap of aluminum faced "Polyester" tape with a parallel uninsulated drain wire.
JacketPVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or in the Internal Wiring of Appliances at temperatures not exceeding 60 deg C.