| Rating | 80 deg C, 600 Vac, Cable flame. |
|
| Conductor | 32 AWG - 4/0 AWG solid or stranded round. |
|
| Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
| Assembly | Two or more insulated singles as described above, twisted pairs or groups of twisted singles twisted together or singles or groups to form a round cable. Lay length not specified. Barrier layers and/or fillers optional. |
|
| Shield | Optional. |
|
| Covering | Optional. A 15 mil or heavier PVC or other thermoplastic material covering extruded over the conductor assembly. The covering used must be suitable to the temperature rating of the cable. |
|
| Jacket | PUR |
| dia. in inches |
| 1.000 or less | 45 mils min average |
| 1.001-1.500 dia | 60 avg |
| 1.501-2.500 dia | 80 avg |
| 2.501-4.000 dia | 110 avg |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring and interconnection of equipment, where the acceptability has been determined by UL LLC. |
|