APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21060 Issued:1999-09-30
Revised:2019-11-07
Style 21060 Multiple conductor with extruded insulation.

Rating80 deg C, 600 Vac, Cable flame.
Conductor32 AWG - 4/0 AWG solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more insulated singles as described above, twisted pairs or groups of twisted singles twisted together or singles or groups to form a round cable. Lay length not specified. Barrier layers and/or fillers optional.
ShieldOptional.
CoveringOptional. A 15 mil or heavier PVC or other thermoplastic material covering extruded over the conductor assembly. The covering used must be suitable to the temperature rating of the cable.
JacketPUR
dia. in inches
1.000 or less45 mils min average
1.001-1.500 dia60 avg
1.501-2.500 dia80 avg
2.501-4.000 dia110 avg
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring and interconnection of equipment, where the acceptability has been determined by UL LLC.