Rating | 200 or 250 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 36 AWG - 14 AWG solid or stranded round. |
|
Insulation | FEP or PFA, 9 mils min average, 8 mils minimum at any point. |
|
Assembly | Two to 150 conductors laid parallel with integral or non-integral insulation and jacket. |
|
Shield | Optional. |
|
Jacket | FEP or PFA, 10 mils min average thickness, 8 mils min thickness at any point. Sections of the cable may be split into singles or groups of conductors. |
|
Misc. | FEP rated 200C, PFA rated 250C |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment (such as computers and electric business machines). |
|