Rating | 60 deg C, 80 deg C, Voltage not specified, Horizontal flame. |
|
Conductor | 12 AWG - 1 AWG stranded round, tinned or bare copper. Inner Conductor - 12 AWG consists of 22 bundled wires with a minimum diameter of 5.8 mm. Each bundle consists of 36 strands of 0.07 mm diameter. Outer Conductor - 1 AWG consists of 30 bundled wires. Each bundle consists of 129 strands of 0.05 mm diameter. |
|
Insulation | Inner and outer insulation- TPE(THERMOPLASTIC ELASTOMER) 15 mils min average, 13 mils minimum at any point. Outer can also use PVC. |
|
Assembly | Two conductors. Inner conductors served around a solid PVC filler, then with first tape, inner insulation, outer conductor served over the insulation, second tape, outer insulation, optional inner shield, third tape, inner jacket, optional outer shield, optional fourth tape and overall outer jacket. |
|
Shield | Inner and outer shield - (Optional) applied over the core with a minimum 85% coverage. |
|
Jacket | Inner Jacket - TPE or PVC, 15 mils min average, 13 mils min at any point. Outer- PVC(POLYVINYL CHLORIDE) 45 mils min average, 36 mils minimum at any point. |
|
Misc. | First, second, third and fourth tape - PTFE 2 mils (0.056 mm) thick. Fourth is optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external interconnection of electronic equipment. |
|