APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2107 Issued:1959-05-01
Revised:2012-03-09
Style 2107 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 12 AWG solid or stranded round, tinned or bare.
InsulationExtruded FRPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyThree conductors.
ShieldShielding over one or more insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or in the Internal Wiring of Appliances.