Rating | 80 deg C, 300 Vac, Cable flame |
|
Conductor | 30 AWG - 16 AWG solid or stranded, coated or bare. |
|
Insulation | Extruded FEP, 5 mils minimum average thickness, 4 mils minimum thickness at any point |
|
Misc. | Coaxial member - FEP Insulation. Overall average thickness 20 mils, 18 mils minimum thickness at any point, braided shield. FEP jacket, minimum average thickness 5 mils, 4 mils minimum thickness at any point. |
|
Assembly | Two or more insulated singles or coaxial members and fillers in any combination may be twisted together to form flat, oval, or round cable, with optional covering, optional shield and overall jacket. Lay not specified. |
|
Shield | Optional |
|
Covering | Optional |
|
Jacket | Extruded PUR |
| Diameter of core assembly under jacket (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.250 or less | 15 | 12 |
| 0.251-0.700 | 30 | 24 |
| 0.701-1.000 | 60 | 48 |
| 1.001-1.500 | 80 | 64 |
| ¿ Major diameter if cable is flat or oval |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General |
|
Use | Test probe lead cable where the acceptability of the combination has been determined by Underwriters Laboratories Inc. |
|