APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2108 Issued:1959-05-01
Revised:2011-10-14
Style 2108 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded, tinned or bare.
InsulationExtruded PE or extruded FRPE, 31 mils minimum average thickness, 28 mils minimum thickness at any point.
AssemblyFour insulated conductors with an overall jacket.
ShieldShielding over one or both insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 31 mils minimum average thickness, 25 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-up and Volume Control or in the Internal Wiring of Appliances at temperatures not exceeding 60 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024