Rating | 75 deg C, 300 Vac, Cable flame. |
|
Conductor | 30 AWG - 4/0 AWG solid or stranded round, tinned or bare copper. May include mixed AWG sizes. |
|
Insulation | Labeled or complying with Manufacture's AWM Procedure. |
|
Assembly | Two or more insulated singles twisted together. Lay not specified. Fillers and/or barrier layers optional. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional. A 6 mil, or heavier, FRPE covering may be extruded over conductor assembly. |
|
Shield | Optional. |
|
Jacket | FRPE |
| dia. in inches |
| 0.700 or less | 25 mils min average | 20 mils minimum at any point |
| 0.701-1.00 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501-4.000 dia | 110 avg | 88 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances and external interconnection of electronic equipment. |
|