Rating | 150 deg C, 30 Vac, Horizontal flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure and having a minimum rating of 150 C and 30 V. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together or two or more conductors or groups may be laid parallel to form flat, oval, or round cables. If more than one group is used, groups may also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional |
|
Jacket | ETFE |
| dia of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.425 inch or less | 15 mils | 13 mils |
| 0.426-0.700 inch | 30 mils | 26 mils |
| 0.701-1.500 inch | 45 mils | 40 mils |
| 1.501-2.500 inch | 60 mils | 55 mils |
| 2.501 inch and larger | 90 mils | 82 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment, Class 2 Circuits only, where not subjected to movement or mechanical damage. |
|