APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21084 Issued:2000-04-10
Revised:2019-11-12
Style 21084 Jacketed Cord.

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor14 AWG - 10 AWG stranded copper.
InsulationPVC
14-12 AWG conductor size15 mils min average13 mils minimum at any point
10 AWG20 avg18 min
AssemblyThree insulated conductors, same as type ST, laid paralled forming a flat cable, with nylon jacket and overall jacket. A web, min 40 mils thick and 100 mils high.
CoveringOptional.
JacketPVC
conductor size
14 AWG60 mils min average48 mils minimum at any point
12-10 AWG75 avg60 min
Misc.Nylon Jacket - 4 mils min over the PVC insulation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn the manufacture of Special Use Cord Sets where extra-hard-usage cord is required and where the acceptability of the combination is determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024