Style 21091 Multiple conductor cable using non-integral covering.

Rating250 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 2 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to twenty insulated singles, cabled together, with or without a shield, barrier layer and covering forming a round or oval cable. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable.
ShieldOptional.
CoveringBarrier over shield, PTFE/GLASS Tape. Covering: Spiral wrapped, Bonded PTFE Tape, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment or appliances.