APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21092 Issued:2000-05-18
Revised:2011-10-26
Style 21092 Multiple-conductor cable using non-integral covering.

Rating150, 200 deg C, 1000 Vac, Horizontal flame.
Conductor30 AWG - 10 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure, 20 mils min average, 18 mils minimum at any point.
AssemblyTwo to twenty insulated singles, cabled together, with or without a shield, barrier layer and covering forming a round or oval cable. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable.
ShieldOptional.
CoveringInner layer - Optional-PTFE/GLASS Tape.; Outer layer - Spiral wrapped, Bonded PTFE Tape, 7 mils min at any point or a Polyaramid or Glass Braid with a Silicone or acrylic based emulsion finished.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024