APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21095 Issued:2000-05-17
Revised:2012-03-14
Style 21095 Multi-conductor cable using non-integral jacket.

Rating60 deg C, 300 V, FT2 or Cable flame.
Conductor28 AWG - 15 AWG solid electrical phosphorescent coated copper. Same conductor sizes.
InsulationExtruded PE, 13 mils min average, 12 mils minimum at any point.
AssemblyTwo or more PE insulated twin conductors laid in parallel, helically twisted together with PVC fillers around a centre PVC filler. An overall PVC jacket employed over this construction.
FillersPVC fillers with or without strength members.
JacketExtruded PVC, 60 mils min average, 48 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Internal or External Use where not subjected to direct sunlight.

UL and the UL Logo are trademarks of UL LLC © 2024