Rating | 60 deg C, 600 Vac, Cable flame. |
|
Conductor | 40 AWG - 4 AWG solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional, a 6 mil or heavier extruded PVC covering may be extruded over the conductor assembly. |
|
Jacket | Extruded PVC |
| dia. in inches |
| 0.425 or less | 30 mils min average | 24 mils min at any point |
| 0.426-0.700 dia | 60 | 48 |
| 0.701-2.500 dia | 80 | 64 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external interconnection of electronic equipment. |
|