|
Rating | 80 deg C, 30 Vac, Cable flame (construction A), Horizontal flame (construction B). |
|
Conductor | 40 AWG minimum. |
|
Insulation | Labeled or complying with Manufacture's AWM Procedure having a minimum rating of 80 deg C, 30 V. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | FRPE. |
| Dia. under jacket | Minimum average for Construction A External Use | Minimum at any point for Construction A External Use | Minimum average for Construction B Internal Use | Minimum at any point for Construction B Internal Use |
| 0.350 inch or less | 20 mils | 17 mils | 15 mils | 12 mils |
| 0.351-0.700 inch | 30 mils | 24 mils | 30 mils | 24 mils |
| 0.701-1.000 inch | 40 mils | 36 mils | 40 mils | 36 mils |
| 1.001-1.500 inch | 54 mils | 48 mils | 54 mils | 48 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal wiring or external interconnection of electronic equipment in Class 2 circuits only. Construction B: Internal wiring of electronic equipment in Class 2 circuits only. |
|