APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21102 Issued:2000-07-14
Revised:2011-08-11
Style 21102 Multiple Conductor with Extruded Insulation and Extruded Non-Integral Jacket

Rating60 deg C, 30 Vac, Horizontal flame
Conductor40 AWG - 2000 kcmil
InsulationExtruded Foamed or Solid PVC, 4 mils minimum average thickness
AssemblyTwo conductors or two groups of twisted singles (thirty conductors max.) may be laid parallel to form flat cable, or two or more twisted singles or groups of twisted singles cabled together. Fillers and barrier layer optional.
ShieldOptional
CoveringOptional. Extruded PVC, Polyamide, ETFE, or Polyester 2 mils minimum thickness at any point, or lacquered braid. May be irradiated.
JacketExtruded PVC, 5 mils minimum average thickness, 3 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal Wiring of Class 2 circuits in Electronic Equipment

UL and the UL Logo are trademarks of UL LLC © 2024