APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2111 Issued:1959-05-01
Revised:2012-03-02
Style 2111 Multiple-conductor cable using non-integral jacket

Rating80 deg C, Voltage not specified, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationPVC, 8 mils min average, 6 mil minimum.
AssemblyFour conductors.
ShieldShielding over one or both conductors shall consist of No. 36-30 AWG. tinned or untinned, copper strands applied as a wrap or braid.
CoveringLacquered braid.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-up and Volume Control or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024