Rating | 80 deg C, 30 Vac, Horizontal, Cable flame. |
|
Conductor | 50 AWG - 2000 kcmil. Solid or stranded round. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Two or more jacketed members may be bonded together forming a flat cable. |
|
Shield | Optional. |
|
Covering | Optional. A 10 mil or heavier extruded THV covering may be extruded over the conductor assembly. |
|
Jacket | Extruded THV, Internal use - 10 mils minimum average thickness, 8 mils minimum thickness at any point; Extruded THV, External use - |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|