APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21113 Issued:2000-08-08
Revised:2019-11-07
Style 21113 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal or cable flame.
Conductor50 AWG - 2000 kcmil solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Two or more jacketed members may be bonded together forming a flat cable.
ShieldOptional.
CoveringOptional. A 10 mil or heavier THV covering may be extruded over the conductor assembly.
JacketExtruded THV
usemajor diameter in inchesmils min average thicknessmils min at any point
internal1.500 or less108
external0.700 inches or less3024
0.701-1.0004536
1.001-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024