Rating | 75, 80 deg C, 1000 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 4/0 AWG solid or stranded round, tinned or bare copper. May include mixed AWG sizes. |
|
Insulation | Labeled or complying with Manufacture's AWM Procedure. |
|
Assembly | Two or more insulated singles twisted together. Lay not specified. Fillers, Shields, Braids and/or barrier layers description of each assembly. |
|
Covering | Optional. A 6 mil or heavier FRPE covering may be extruded over the conductor assembly. |
|
Jacket | Extruded FRPE |
| dia. in inches |
| 0.400 or less | 25 mils min average | 20 mils minimum at any point |
| 0.401-0.700 dia | 35 avg | 28 min |
| 0.701-1.000 dia | 48 avg | 38 min |
| 1.001-1.500 dia | 64 avg | 51 min |
| 1.501-2.500 dia | 60 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances. |
|