APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21116 Issued:2000-09-06
Revised:2011-10-06
Style 21116 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 150 Vac, 300 Vac peak, Cable flame.
Conductor33 AWG - 18 AWG, solid or stranded, round or tinsel.
InsulationExtruded PE, 5 mils minimum average thickness, 4 mils minimum thickness at any point.
AssemblyTwo or more insulated conductors, lay not specified.
ShieldRequired.
JacketExtruded XLPE
Dia. under jacket in inchesMinimum average thicknessMinimum thickness at any point
0.350 inch or less25 mils20 mils
0.351-0.700 inch30 mils24 mils
0.701-1.000 inch40 mils36 mils
1.001-1.500 inch54 mils48 mils
CoveringOptional. Extruded PE, 2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHandset Wire or Telephone Cord for Subscriber Sets, or Internal or External Interconnecting Cable of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024