Rating | 60 deg C, 150 Vac, 300 Vac peak, Cable flame. |
|
Conductor | 33 AWG - 18 AWG, solid or stranded, round or tinsel. |
|
Insulation | Extruded PE, 5 mils minimum average thickness, 4 mils minimum thickness at any point. |
|
Assembly | Two or more insulated conductors, lay not specified. |
|
Shield | Required. |
|
Jacket | Extruded XLPE |
| Dia. under jacket in inches | Minimum average thickness | Minimum thickness at any point |
| 0.350 inch or less | 25 mils | 20 mils |
| 0.351-0.700 inch | 30 mils | 24 mils |
| 0.701-1.000 inch | 40 mils | 36 mils |
| 1.001-1.500 inch | 54 mils | 48 mils |
|
Covering | Optional. Extruded PE, 2 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Handset Wire or Telephone Cord for Subscriber Sets, or Internal or External Interconnecting Cable of Electronic Equipment. |
|