APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21119 Issued:2000-10-13
Revised:2019-11-07
Style 21119 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 150 Vac, Cable flame.
Conductor36 AWG - 9 AWG, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors laid parallel or cabled together to form a flat, oval or round cable. Conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. The use of a barrier layer and/or fillers is optional. Cable may contain Labeled Flat Ribbon Style AWM which may be rolled or spiralled and formed around fillers or bunched singles. Fillers and/or tape wrap or extruded covering may be used.
ShieldOptional. The shield may be over one or more of the insulated conductors or applied between the conductor assembly and the optional covering.
CoveringOptional.
JacketFRPE
dia. in inches
1.000 or less30 mils min average24 mils minimum at any point
1.001-1.500 dia45 avg36 min
1.501-2.500 dia60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.