APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2112
Issued:
1959-05-01
Revised:
2011-08-29
Style
2112
Insulated Shielded Cable
Rating
80 deg C, 300 Vac (Insulation), 600 (Jacket), Horizontal flame.
Conductor
26 AWG - 16 AWG solid or stranded round, tinned or bare copper.
Insulation
PVC, 15 mils min average, 14 mils minimum at any point.
Assembly
Two conductors.
Shield
Shielding over one or both insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
Jacket
PVC, 30 mils min average, 24 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Phonograph Pick-up and Volume Control or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.