APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2112 Issued:1959-05-01
Revised:2011-08-29
Style 2112 Insulated Shielded Cable

Rating80 deg C, 300 Vac (Insulation), 600 (Jacket), Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationPVC, 15 mils min average, 14 mils minimum at any point.
AssemblyTwo conductors.
ShieldShielding over one or both insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-up and Volume Control or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.
 