APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21121 Issued:2000-11-09
Revised:2011-09-26
Style 21121 Multiconductor Cable With Extruded Non-Integral Jacket

Rating80 deg C, 90 Vac, Cable flame (external use), Horizontal Flame (internal use).
Conductor30 AWG - 16 AWG.
InsulationExtruded HDPE, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyConsists of two conductors, twisted pairs or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval or round cable construction. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection not subject to mechanical abuse.