Rating | 80 deg C, 90 Vac, Cable flame (external use), Horizontal Flame (internal use). |
|
Conductor | 30 AWG - 16 AWG. |
|
Insulation | Extruded HDPE, 7 mils minimum average thickness, 6 mils minimum thickness at any point. |
|
Assembly | Consists of two conductors, twisted pairs or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval or round cable construction. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. |
|
Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection not subject to mechanical abuse. |
|