APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21127 Issued:2001-01-25
Revised:2019-11-07
Style 21127 Multiconductor Cable with Extruded Non-Integral Jacket

Rating60, 75 deg C, 600 Vac, Cable flame.
Conductor32 AWG - 4/0 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more insulated singles as described above, twisted pairs or groups of twisted singles twisted together or singles or groups laid to form a round cable. Lay length not specified. Barrier layers and/or fillers optional.
ShieldOptional.
CoveringOptional - A 15 mil or heavier PVC or other thermoplasticmaterial covering extruded over the conductor assembly. Thecovering used must be suitable to the temperature rating ofthe cable.
JacketPUR
dia. in inches
1.000 or less45 mils min average36 mils minimum at any point
1.001-1.50 dia60 avg48 min
1.501-2.50 dia80 avg64 min
2.501-4.000 dia110 avg88 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection.