APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2113 Issued:1959-05-01
Revised:2008-05-27
Style 2113 Insulated Shielded Jacketed Cable

Rating80 deg C, 300 Vac (Insulation), 600 (Jacket), Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded round, tinned or bare copper.
InsulationPVC, 15 mils min average, 14 mils minimum at any point.
AssemblyThree conductors.
ShieldOver one or more insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.
 