APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2113
Issued:
1959-05-01
Revised:
2008-05-27
Style
2113
Insulated Shielded Jacketed Cable
Rating
80 deg C, 300 Vac (Insulation), 600 (Jacket), Horizontal flame.
Conductor
26 AWG - 16 AWG, solid or stranded round, tinned or bare copper.
Insulation
PVC, 15 mils min average, 14 mils minimum at any point.
Assembly
Three conductors.
Shield
Over one or more insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
Jacket
PVC, 30 mils min average, 24 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Phonograph Pick-Up and Volume Control; or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.