APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21130 Issued:2001-01-26
Revised:2012-04-20
Style 21130 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 60 Vac, Horizontal flame.
Conductor50 AWG min.
InsulationExtruded PVC, extruded foamed PVC, extruded XLPVC, extruded PE, extruded foamed PE, extruded XLPE, extruded FRPE, extruded foamed FRPE, extruded XLFRPE, extruded Polyester or extruded foamed polyester, or extruded XLPolyester, 2 mils min average.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Two or three conductors and or conductor groups may be laid parallel to form flat cable. The assembly - insulated conductors with optional inner shield, optional inner covering, optional middle covering, optional middle shield, optional outer covering, optional outer shield and overall jacket. Manufacturer shall maintain a complete description of each assembly.
ShieldInner, middle and outer shield are optional.
CoveringInner and outer covering- (Optional)Extruded PVC, 2 mils minimum at any point, or Polyester film, thickness not specified. Middle covering- (optional)Extruded PVC, Polyamide, Polyester or Lacquered Braid.
JacketExtruded FRPE, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024