APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21132 Issued:2001-03-05
Revised:2012-08-17
Style 21132 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating90 deg C, 1000 Vac, Cable flame
Conductor40 AWG minimum solid or stranded
Insulated ConductorLabeled or complying with Manufacturer's AWM Procedure
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional
CoveringOptional - Extruded PVC, 6 mils minimum thickness at any point
JacketExtruded PVC
@Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch60 mils48 mils
1.001-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
@ Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring or external interconnect of electronic equipment