APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21134 Issued:2001-03-07
Revised:2019-11-04
Style 21134 Multiple conductor with non-integral jacket

Rating150 deg C, 75 Vac, Cable flame.
Conductor36 AWG - 20 AWG.
InsulationFEP, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo or more insulated singles optionally twisted around a flouropolymer filler or breather tube. Fillers may be used to form round cable.
Inner jacketOptional, Silicone rubber, 20 mils min average, 24 mils min at any point. .
ShieldOptional.
JacketSilicone Rubber
Dia. of round assembly under jacket (inch)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.200 or less3024
0.201 - 0.3004536
0.301 - 0.4006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInterconnecting Cable for Medical Instruments.

UL and the UL Logo are trademarks of UL LLC © 2024