APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21135 Issued:2001-03-07
Revised:2011-10-17
Style 21135 Multiconductor Cable with Non-Integral Jacket.

Rating150 deg C, 125 Vac, Cable flame.
Conductor36 AWG - 20 AWG solid or stranded round.
InsulationExtruded PFA, 7 mils min average, 6 mils min at any point.
AssemblyTwo or more insulated singles optionally twisted around a fluoropolymer filler or breather tube. Fillers may be used to form round cable.
Inner JacketOptional, SR (Silicone rubber), 30 mils min average, 24 mils minimum at any point.
ShieldOptional.
Outer JacketSR (Silicone Rubber);
thickness of core od in inchesMinimum average thicknessMinimum thickness at any piont
0.200 or less30 mils24 mils min at any point
0.201-0.30045 avg36 min
0.301-0.40060 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInterconnecting Cable for Medical Instruments