APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21137 Issued:2001-03-29
Revised:2012-04-18
Style 21137 Multiple-conductor cable using non-integral jacket

Rating75 deg C, 600 Vac, Horizontal flame.
ConductorMinimum 50 AWG. Solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024