Rating | 80 deg C, 300 Vac (Insulation), 600 Vac (Jacket), Horizontal flame. |
|
Conductor | Four, 26 AWG - 16 AWG, solid or stranded. |
|
Insulation | PVC, 15 mils minimum average, 13 mils minimum at any point. |
|
Shield | Shielding over one or more insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
|
|
Jacket | PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Phonograph Pick-up and Volume Control; or In the Internal Wiring of Appliances. |
|