APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2114 Issued:1959-05-01
Revised:2011-08-04
Style 2114 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac (Insulation), 600 Vac (Jacket), Horizontal flame.
ConductorFour, 26 AWG - 16 AWG, solid or stranded.
InsulationPVC, 15 mils minimum average, 13 mils minimum at any point.
ShieldShielding over one or more insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-up and Volume Control; or In the Internal Wiring of Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024