|
Rating | 60 deg C, 30 Vac, Cable flame. |
|
Conductor | 36 AWG min. solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure and having a min rating of 60 deg. C and 30 V. The designations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; thermoplastic covering, or thermoplastic-tape wrap. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded TPU. |
| Dia of Cable Under Jacket - In. | Min. Average Thickness - Mils | Min. At Any Point Thickness - Mils |
| 0.700 or less | 30 | 24 |
| 0.701 - 1.000 | 45 | 36 |
| 1.001 - 1.500 | 60 | 48 |
| 1.501 - 2.500 | 80 | 64 |
| 2.501 - 4.000 | 110 | 88 |
| 4.001 and larger | 140 | 112 |
| - Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|