APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21145 Issued:2001-04-26
Revised:2011-09-19
Style 21145 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 1000 Vac, Cable flame.
ConductorSolid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors laid parallel or cabled together to form a flat, oval or round cable. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded FRPE.
Diameter of core assembly under jacketMinimum average thicknessMiniimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.010-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal.