Rating | 80 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 26 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point. |
|
Assembly | Two conductors. |
|
Shield | Shielding over one or both conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid or a wrap of aluminum faced Polyester tape with a parallel uninsulated drain wire. |
|
Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|