Rating | 60 deg C, 150 Vac, Cable flame. |
|
Conductor | 30 AWG - 16 AWG solid or stranded round, tinned or bare copper or copper alloy. |
|
Insulation | PE, 5 mils min average, 4 mils minimum at any point. |
|
Assembly | Two or more insulated singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Required, aluminum foil and polyester binder tape. |
|
Covering | Optional. |
|
Braid | Optional. |
|
Jacket | FRPE, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring or External Interconnection of electronic equipment. |
|