APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21156 Issued:2001-07-09
Revised:2012-04-25
Style 21156 Multiple-conductor cable using non-integral jacketed.

Rating60, 75 deg C, 600, 1000 Vac, Cable flame.
Conductor30 AWG - 4/0 AWG solid or stranded round. May include mixed AWG sizes.
InsulationLabeled or complying with Manufacture's AWM Procedure.
AssemblyTwo or more insulated singles twisted together. Lay not specified. Fillers and/or barrier layers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional. A 6 mil, or heavier, thermoplastic covering may be extruded over conductor assembly.
ShieldOptional.
JacketExtruded FRPE
dia. under Jacket in inchesMin average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or external interconnection of electronic equipment.