APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2116 Issued:1959-05-01
Revised:2011-09-27
Style 2116 Multiple-conductor cabl using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblyThree conductors.
ShieldShielding over one or more insulated conductors shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.