Rating | 60, 80, 90 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 50 AWG minimum. |
|
Insulation | Integral with Jacket. Extruded ETFE or FEP or PFA or PTFE, TFE, 2 mils minimum average thickness. |
|
Assembly | Insulated single or group of insulated singles laid parallel or twisted together, with optional inner covering, optional middle covering, optional inner or outer shield, optional outer covering, length of lay not specified. Barrier layer or fillers optional. Either inner or outer shield is required, additional shield optional. |
|
Shield | Inner - (Optional) Required if outer shield not provided. Outer Shield - (Optional) Required if inner shield not provided. Material not specified. |
|
Covering | Inner Covering - (Optional) Extruded PVC, Polyethylene or Irradiated Polyethylene, or PFA, or Polyester film. Thickness not specified.
Middle covering - (Optional) Extruded PVC, or PFA, Polyamide, Polyester, PVDF, FEP or PTFE, ECTFE, ETFE, or lacquered braid, or heat sealed PVC tape,or tape wrapped PTFE Polyester film or Polyester-Polyethylene laminated film. Thicknesses not specified.
Outer Covering - (Optional) REQUIRED IF OUTER SHIELD IS PROVIDED. Extruded PVC, or PFA, Polyamide, Polyester, PVDF, FEP, PTFE, ECTFE, ETFE, irradiated PE, irradiated PVC Polyurethane,or heat sealed PVC tape, or lacquered braid, thicknesses not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Class 2 circuits of electronic equipment or as insulated single in jacketed multiconductor cables. |
|